UK flood barrier supplier since 2012 Sole UK distributor of Water-Gate

Services · Waterproofing

Waterproofing for flood resistance.

Masonry preparation, repointing and suitable waterproofing treatments can help reduce water ingress through walls and support the performance of flood barriers, as part of a considered flood protection scheme.

Part of a flood protection scheme
Masonry prep, repointing, treatments
Considered, not off-the-shelf
A water-repellent masonry cream being brushed onto brickwork
Specialist flood protection since 2012
  • Engineer-led advice
  • Made-to-measure systems
  • Quotes from your photos and measurements
  • Professional installation in selected areas

An overlooked route

Floodwater can enter through walls, too.

Doors and openings are the first thing people protect. The surrounding walls are an overlooked route, even once a barrier is in place.

Doors and openings are the first thing people protect; the surrounding walls are an overlooked route, even once a barrier is in place.

Brick, stone and mortar vary in how readily they absorb water, and water can pass through deteriorated joints, small cracks, gaps around pipes and material interfaces; under sustained pressure, minor defects allow significant seepage.

Understanding these routes helps decide whether masonry repairs or waterproofing should accompany a barrier installation.

Positive and negative

Positive and negative waterproofing explained.

"Positive" and "negative" describe which side of the structure receives the waterproofing relative to the water pressure.

A cross-section diagram showing positive waterproofing on the outer, water-facing face of a wall and negative waterproofing on the inner face
01

Positive: treatment on the water-facing side

Applied to the side facing the incoming water, usually the outside during an external flood; resists water before it passes into the wall. External measures may include a suitable waterproof render or coating; water-repellent treatments and repointing can form part of an external approach, though they do not all resist standing floodwater equally.

02

Negative: treatment on the inside

Applied to the internal face; water may enter the masonry while the internal layer resists its passage into the room. Internal tanking is one example, and must withstand pressure from behind and connect correctly with floors and junctions; the wall can stay wet, so the effect on the fabric needs thought.

Creams and mortar

Masonry creams and repointing.

Water-repellent creams such as Stormdry can reduce absorption into suitable brick, stone and mortar, but a cream cannot close cracks or repair gaps, so joint condition matters and treatment should be considered alongside repointing and repairs. Suitable repointing additives may improve the mortar’s water resistance and bond.

The mortar, additive and treatment must be compatible with the building; the strongest or least permeable mix is not automatically right.

Accessible spaces

Tanking garages and accessible spaces.

A garage with exposed masonry walls and a bare concrete floor

Garages can be a relatively straightforward setting for internal tanking where masonry walls and a concrete floor are already exposed, with fewer finishes to remove.

A suitable system may be considered alongside a garage flood barrier to reduce seepage; suitability still depends on the condition of the walls and floor, expected pressure and how the waterproofing connects around the space. An accessible wall makes the work easier, but the complete arrangement still needs consideration.

A common weak point

The often-overlooked wall-to-floor junction.

Where a wall meets the floor can be a route for water, even where the wall above is treated. Some tanking systems use a purpose-made fillet seal, a shaped waterproof mortar joint connecting wall and floor treatment; other systems need different details, especially where movement must be accommodated.

The aim is continuity: treating the wall while leaving an unprotected junction, floor crack or gap around a pipe leaves a route in.

A cross-section of the corner where a wall meets a floor, with the tanking on the inner wall face carried down into a shaped fillet seal at the junction and continuing across the floor, and arrows showing water pressure acting from behind the wall and from below the floor slab

Traditional construction

Older and heritage buildings need a different approach.

Traditional buildings often rely on moisture moving through lime mortar, plaster and masonry so the structure can dry; impermeable coatings, unsuitable cement mortars and internal tanking can interfere with this and trap moisture. For some heritage properties these approaches may be unsuitable or unviable.

Material compatibility, drying behaviour and the significance of the building need specialist consideration; appropriate repairs, carefully detailed barriers and recovery measures may suit better.

Where it fits

Part of a considered flood protection plan.

Waterproofing is one potential component of a wider scheme; the right approach depends on construction and condition, likely depth and duration, and the other routes water could take. Keeping water outside also creates pressure on walls and floors, so the structure’s ability to resist it must be considered.

Where a property needs a detailed flood assessment or a strategy to establish suitable measures, this can be commissioned separately through FPS Environmental Ltd.

  • OpeningsProtected by flood barriers and flood doors.
  • WallsThrough masonry preparation, repointing and suitable treatments.
  • AirbricksWith self-closing airbrick protection.
  • DrainsThrough backflow protection and pumping.
  • Floors and below-ground constructionWhere water can rise from beneath.

Treat one route and leave another open, and the property is still exposed.

The seal depends on the wall

A flood barrier needs a suitable surface.

A flood barrier bottom seal and side rail meeting sound, prepared masonry at a doorway

A barrier relies on more than the panel: its fixings, side rails and bottom seal must connect to sound construction. Uneven masonry, recessed joints, loose render and damaged thresholds can prevent a continuous seal or leave bypass routes; preparation may include local repairs, levelling the sealing surfaces, repointing or a suitable threshold.

Where wall treatments form part of the scheme, their connection to the barrier matters, or water may pass through untreated masonry and emerge behind the rails. FPS can consider these interfaces as part of its flood barrier installation works, with any necessary preparation in the agreed scope.

How we get involved

Involving us in your project.

Flood Protection Solutions Ltd is based in Nottingham and considers masonry preparation, repointing and waterproofing where they form part of a flood protection project it is involved in, including barrier installations; involvement depends on the location, scale and requirements of the scheme. We do not offer a general nationwide service for standalone repointing or ad-hoc waterproofing quotations.

01

Advise

Tell us about the scheme

Site address, a brief description of the proposed works, and whether you are seeking flood barriers, installation or involvement in a wider protection scheme.

  • Site address
  • Outline of the proposed works
  • What you are seeking from us
02

Share

Give us the available information

Relevant photographs and details of any existing flood assessment, specification or proposed measures, so we can understand the enquiry and whether it fits our services.

  • Photographs of the walls and openings
  • Any existing flood assessment
  • Any specification or proposed measures
03

Confirm

Agree the next step

We confirm whether the project is suitable for our involvement and explain what is needed before we can define and price the works, which may include a site visit or a separately commissioned assessment.

  • Confirmation that the project suits our services
  • What is needed to define and price the works
  • A site visit or separate assessment where required

If you have a scheme and would like our involvement, please contact us with an outline of the project. Detailed assessment or strategy is commissioned separately through FPS Environmental Ltd.

Barriers and the walls around them

Planning a flood barrier installation?

Talk to us about your scheme and the surrounding construction. Where masonry preparation or waterproofing is appropriate, we can consider it within an agreed installation package.

Contact us.

Tell us about the scheme and the surrounding construction: the site address, an outline of the proposed works, any defects you can see, and whether a flood assessment or specification already exists. That helps us understand whether the project fits our services.

Prefer to talk?

0115 987 0358

Monday to Friday, 9am to 5pm. For a made-to-measure barrier, use the quotation form on our FPS Barrier, Nautilus, door, driveway or garage barrier pages. It takes the measurements and photographs we need.

Send us a message

We normally reply within one working day.

We use these details to reply to your enquiry. See our Privacy Policy (opens in a new tab).

Please note: flood risk assessments, drainage design and consultancy are handled separately by FPS Environmental Ltd.

Contact us Contact us