UK flood barrier supplier since 2012 Sole UK distributor of Water-Gate

For specifiers · Architects

Flood barriers for
architects and specifiers.

We support architects and specifiers with product information, standard drawings, specification data and fixing details for our flood barrier range. Where the opening and required protection are defined, we can help identify suitable product options and provide the relevant information for coordination and tender. Flood-risk assessment, drainage design and wider mitigation design are separate professional services through FPS Environmental Ltd.

Colour-matched flood barrier rails installed on a listed property doorway

Products you can specify

Systems we can help you specify by aperture.

The product pages carry the full detail for each system.

Independently testedFlood barriers tested by independent industry testing Water-GateSole UK distributor
CAD · NBSDrawings and specification clauses supplied
Since 2012Barriers supplied UK-wide and internationally

What we provide at design stage

Specification support.

Product information, standard drawings, specification data and fixing details for the project file, based on the opening information supplied.

01

Options

Product options by aperture

Which barrier suits a door, a wide opening, a driveway or a perimeter, and how it fixes, based on the opening information supplied.

02

Drawings

Standard drawings

Standard product drawings in the formats available for the relevant system.

03

Bespoke

Project-specific drawings

Where a project requires a bespoke or site-specific barrier drawing, this can be prepared separately for an additional fee once the required project information has been provided. Bespoke drawings are not included as standard within a product quotation unless specifically stated.

04

Documents

NBS clauses and technical data

NBS-format specification clauses for tender documents, with technical data and test information, including PAS 1188.

05

Fixings

Fixing arrangements

Reveal-fix and face-fix detail, and the ground fixings and posts used on wide spans.

06

Method

Method statements

Standard installation information is available for applicable products. Project-specific RAMS are provided where FPS is undertaking the relevant installation works.

Designing the barrier

Design integration and what a barrier needs.

High Nautilus flood barrier on wooden doors

A barrier performs only as well as what it seals and fixes onto, so it helps to consider three things at design stage: a flat, level, water-resistant threshold for the barrier to seal against, sound masonry or a suitable structure for the fixings, and the protection height.

Protection height affects the loading transferred into the barrier fixings and supporting structure. Around 600mm is commonly treated as an important threshold for further structural consideration, while some constructions, including single-skin masonry, can require more conservative limits (see our structural guidance for the detailed position).

Colour-matched finishes are available where appearance matters. Getting these into the design early avoids remedial work later.

The resource library

Standard drawings and installation information.

Standard product drawings and standard installation information for the barrier range.

Custom project drawings. Need a project-specific drawing? Bespoke drawings can be prepared separately for an additional fee. Contact us with the project information if this is required.

More drawings, guides and films are in the downloads library.

Flood risk consultancy

Need flood risk advice
before you specify?

FPS Environmental Ltd, the separate consultancy company in the FPS Group, handles the consultancy side: flood risk assessments, drainage design and due diligence for planning and feasibility. It is a separate company to Flood Protection Solutions Ltd, which supplies the barriers.

Part of the FPS Group

Civil engineers and flood risk consultants, working across the UK on planning compliance and project feasibility.

Where assessment is needed

Specifying a product, or assessing the site

Choosing and detailing a barrier for a defined opening is product specification, which we support directly. Establishing the flood risk to a site, the design flood level, and the overall strategy is a flood risk and drainage engineering exercise, and it is provided separately through FPS Environmental. The two work together on integrated projects.

Flood risk assessments Design flood levels Drainage design SuDS design Flood mitigation design Planning support
Visit FPS Environmental

Common questions

Specifying an FPS barrier.

Do you provide CAD drawings and NBS specifications?

We provide standard product drawings in the formats available for the relevant system, along with datasheets and standard installation information. Where a project requires a bespoke or site-specific drawing, this can be prepared separately for an additional fee once the project information is provided; it is not included as standard within a product quotation. NBS clauses and BIM objects are provided where available.

What protection height should I specify?

Protection height affects the loading transferred into the barrier fixings and supporting structure. Around 600mm is commonly treated as an important threshold for further structural consideration, and some constructions, such as single-skin masonry, can require more conservative limits. The right height also depends on the design flood level for the site, which is established by assessment.

Can FPS support a project at design stage?

Yes. We suggest product options by aperture from the opening information supplied, provide the standard technical detail and drawings, and set out fixing arrangements.

Is flood risk consultancy available?

Yes, through FPS Environmental, a separate company in the FPS Group, under a separate professional instruction.

Recent projects

Installations you
would find relevant.

A selection of recent projects: residential retrofits with sensitive aesthetics, commercial fits to NBS specification, and public sector installations under framework agreements.

Sector · Region

Project type

Project name

A sentence or two on what the job involved. Only describe work that was actually done.

Year · Sector Case study →
Sector · Region

Project type

Project name

A sentence or two on what the job involved. Only describe work that was actually done.

Year · Sector Case study →
Sector · Region

Project type

Project name

A sentence or two on what the job involved. Only describe work that was actually done.

Year · Sector Case study →

Get protected

Get specifications and a quote.

Tell us the apertures and the project, and we will recommend systems by opening and provide the drawings, clauses and technical data for the file, with a supply quotation. Flood risk assessment and drainage design are handled separately by FPS Environmental.

Contact us.

Tell us what you are looking for and we will get back to you. For a product enquiry, include the opening or product, its approximate dimensions and the location, so we can give you a specific answer.

Prefer to talk?

0115 987 0358

Monday to Friday, 9am to 5pm. For a made-to-measure barrier, use the quotation form on our FPS Barrier, Nautilus, door, driveway or garage barrier pages. It takes the measurements and photographs we need.

Send us a message

We normally reply within one working day.

We use these details to reply to your enquiry. See our Privacy Policy (opens in a new tab).

Please note: flood risk assessments, drainage design and consultancy are handled separately by FPS Environmental Ltd.