UK flood barrier supplier since 2012 Sole UK distributor of Water-Gate
Water-Gate
Water‑Gate tertiary containment.
Contain contaminated fire water runoff before it reaches a drain, a watercourse or the wider environment. The Water-Gate WL is a flexible-boom tertiary containment measure recognised under CIRIA C736 guidance, for COMAH-regulated sites that are required by law to have a plan to control the water used to fight fires.
COMAH
The regulatory context.
Sites subject to the Control of Major Accident Hazards (COMAH) regulations are required by law to have plans in place to control the water used to fight fires. When water is used to suppress a fire involving hazardous substances, that water becomes contaminated. If it escapes into a drain or a nearby watercourse, the site operator is responsible for the pollution, and for the clean-up costs, the enforcement action and the reputational damage. Depending on your site’s substances and quantities, you may need a permanent containment lagoon, an emergency plan alone, or something in between. The Water-Gate WL fits the in-between: a rapidly deployable tertiary containment measure that supplements existing primary and secondary systems and holds contaminated water in place until it can be removed for treatment.
The guidance
What CIRIA C736 says.
CIRIA C736, Containment systems for the prevention of pollution, is the definitive UK guidance for site-based pollution containment. It defines tertiary containment as measures that:
“minimise the consequences of a failure in the primary and secondary containment systems … such as site drainage and sumps, diversion tanks and lagoons, containment kerbing to roadways and parking areas and impervious liners and/or flexible booms.”
CIRIA C736
The guidance specifically identifies flexible booms as a recognised tertiary containment option for events including “firewater overflowing from a bund or escaping from building or warehouse during a prolonged fire.” The Water-Gate WL is a flexible boom, so CIRIA C736 names our product category.
CIRIA C736 (2014). Available from CIRIA.
In a fire
How it works in a firewater scenario.
- Anticipate the flow path. Where would contaminated water go from your site: which drains, which gradients, which watercourses? Identify the critical interception points.
- Store barriers close to those points. Water-Gate WLs roll up small, weigh manageable amounts, and store on a shelf or in a rapid deployment crate.
- Deploy as an intercept. Two people can roll out a barrier across a road, drain approach or overflow route in under five minutes.
- Contain and remove. The barrier holds the contaminated water until vacuum tankers or pumping equipment can transfer it for treatment.
Video
Firewater runoff control with the Water‑Gate barrier.
A short film showing how the Water-Gate barrier is used to control firewater runoff. Nothing loads from YouTube until you press play.
The model
Why the WL is the right model for tertiary containment.
The WL Water-Gate is our primary model for firewater runoff. It has integrated ballast weights along the leading edge, deploys faster than any other model, and is chemically resistant, having been independently tested with commercial solvents. Manufacturer test data show the fabric resisting for at least 12 hours against a wide range of firewater contaminants, including hydrochloric acid, caustic soda, gasoline, diesel, oil, hydrogen peroxide and bleach; a few aggressive chemicals, such as sulfuric and nitric acid and some chlorinated and polar solvents, are not recommended, so confirm your site’s substances with us. It can be stored ready to go and driven over between deployments, and in the manufacturer’s engineering tests it is designed with a large safety margin. The WL39, WL50 and WL60 series are FM Approved to Silver certification following full testing by the US Army Corps of Engineers.
Product and plan
Pairing product with plan.
Deploying a barrier is only half the answer. The other half is knowing when and where to deploy it, and that is the firewater runoff plan. Fire Prevention Plans are required by the Environment Agency as a condition of an Environmental Permit, and the plan should be prepared in accordance with CIRIA guidance on containment systems for the prevention of pollution.
Part of the FPS Group
Civil engineers and flood risk consultants, working across the UK on planning compliance and project feasibility.
The engineering review
Firewater runoff plans and site modelling
This is an engineering review, so it is provided through FPS Environmental Ltd, the separate consultancy company in the FPS Group, working with leading environmental consultants to model firewater flow paths, size containment volumes and write the site emergency response documentation. If you need consultancy alongside the product, we can bring both together. See firewater runoff consultancy.
Questions to consider
Is your site ready?
A firewater plan should consider site drainage (where the drains go, clean water to surface-water drains and contaminated water to foul drains, and whether there is an up-to-date drainage plan), the storage of oils, chemicals and polluting materials (fit-for-purpose inspected containers, secondary containment such as bunds, and safe delivery and handling), waste management, and emergency response (a plan, equipment and training, tested regularly). If you cannot answer these, seek advice from our team.
Evidence
Trialled by Shropshire Fire and Rescue Service.
The Water-Gates performed effectively in trials and they would have helped to enable polluted water to be transported away from the risk area. The Water-Gates are ideal for this type of project and would have minimised any further risks of pollution if used in anger.
Who we work with
Regulated and industrial clients.
Case studies
Water‑Gate deployments by fire and rescue services.
Two projects already documented on this site: pollution contained on the River Severn, and a county fire service equipping its teams with Water-Gate barriers.
Shropshire Fire and Rescue Service · River Severn
Pollution containment
Pollution Control – River Severn
A Water-Gate barrier deployed on the River Severn to contain pollution in the watercourse while allowing clean water to keep flowing through.
Essex County Fire and Rescue Service · Essex
Rapid deployment barriers
Are you prepared? Essex Fire & Rescue are.
Essex Fire and Rescue equipped their teams with Water-Gate barriers so they can hold back floodwater quickly at incidents, rather than relying on sandbags.
Buy online
Buy online or contact us.
WL Water-Gate barrier. Buy online, or use the contact form for a specific site.
For a bespoke scheme, use the contact form.
Questions
Common questions.
What is tertiary containment?
The additional line of containment that stops fire water or a spill reaching a watercourse if the primary and secondary systems fail or overflow. CIRIA C736 names flexible booms as a recognised tertiary containment option, and the Water-Gate WL is a flexible boom.
Do I need a consultant?
For a Fire Prevention Plan or site modelling, yes. That engineering review is provided through FPS Environmental. For the barrier itself, we can supply directly.
Can it contain chemicals as well as firewater?
It is chemically resistant and has been independently tested with commercial solvents. Confirm suitability for your specific substances with us.
Contact us.
Tell us the length of the run, the water height you expect, what the barrier is for, the site postcode and your timescale. We will then specify the model, height and length.
Prefer to talk?
Monday to Friday, 9am to 5pm. For a made-to-measure barrier, use the quotation form on our FPS Barrier, Nautilus, door, driveway or garage barrier pages. It takes the measurements and photographs we need.
Send us a message
We normally reply within one working day.
We use these details to reply to your enquiry. See our Privacy Policy (opens in a new tab).
Please note: flood risk assessments, drainage design and consultancy are handled separately by FPS Environmental Ltd.