UK flood barrier supplier since 2012 Sole UK distributor of Water-Gate

Backflow protection

Backflow protection & non-return valves.

Sewer surcharge can push foul or surface water backwards through drains and into a property. Non-return valves can reduce this risk, provided they are installed on the correct drainage run and in a suitable location. We supply and install backflow protection for homes, commercial premises and PFR projects, from simple retrofit valves to chamber-mounted solutions.

Supply & installation
Simple cases priced quickly
Complex drainage understood first
A full-port non-return valve installed in a new inspection chamber, before the paving is reinstated

The range

Types of backflow protection.

Different drainage arrangements need different protection. The right solution depends on the type of drainage, the pipe, the access and how the valve will be inspected and maintained.

A full-port non-return valve with a clear inspection lid, fitted to a drainage run before the chamber is built

01

Full-port non-return valve

Usually installed within an inspection chamber or manhole. A largely unobstructed route in normal conditions; closes on reverse flow. Useful on a main drainage run.

An inline WaPro non-return valve fitted within a waste pipe against an external wall

02

Inline non-return valve

Installed directly within a drainage pipe. A neat solution where the run is known and there is access for inspection and maintenance.

Two push-fit non-return valves fitted to the pipe inlets inside an inspection chamber

03

Push-fit non-return valve

A simple retrofit for suitable arrangements. Products such as the Buffalo valve can cost under £100. The key is confirming it is on the run that actually needs protection.

Two 40mm wastewater non-return valves fitted to waste pipes at the base of an external wall

04

Wastewater non-return valves

For foul drainage where wastewater and solids pass through in normal operation. Must suit the application, pipe size and arrangement.

A Panseal fitted to a WC to stop surcharge entering through the pan

05

Panseal

Localised protection preventing surcharge entering through a WC. A last-resort or highly localised measure where backflow cannot practicably be addressed elsewhere.

Location matters

The valve may be simple. The drainage is the important part.

Some installs are very straightforward: a known run and a clear surcharge route. Others have several runs, shared sewers, basement connections, deep chambers or historic drainage that is not clearly understood. A valve in the nearest convenient chamber may not solve the problem, because another connection can bypass it entirely.

The appropriate solution should be determined by the drainage network, rather than by starting with a particular product.

  • Where surcharge can reach the property, and whether drainage is foul, surface or combined
  • How the runs connect, pipe sizes, materials and condition
  • Whether another pipe could bypass the proposed protection
  • What happens to drainage generated inside while the valve is closed

Both directions

What happens when the valve closes?

In normal conditions a non-return valve lets water flow towards the sewer. When the sewer surcharges, it closes to stop water travelling back. But while it is closed, water generated upstream, from toilets, showers, sinks, washing machines and roof drainage, cannot flow out that way either.

Approved Document H states that drainage unaffected by surcharge should bypass the protective measures and continue to discharge by gravity. A good solution answers both questions: what are we keeping out, and where does inside water go while the valve is shut?

Whole-property

Don’t protect the doorway and forget the drainage.

Diagram showing floodwater held back by a flood barrier at the surface while floodwater or surcharge travels under the barrier through a drainage pipe into the protected property

Barriers and walls hold floodwater outside, creating a difference in water level and pressure between outside and inside. Where drainage crosses that line, it can be another route in. A barrier across a driveway is of limited benefit if water can travel underneath it through the drains, so drainage and backflow should be considered alongside any perimeter protection scheme.

Watch

Understanding backflow protection.

Loading the video

Simon Crowther BEng (Hons) FCIWEM C.WEM explains how sewer surcharge occurs through toilets and drains, how non-return valves operate, and why both the valve and its location matter.

Design & regulations

Designing backflow protection properly.

Installs range from a simple valve in an accessible pipe to a new chamber or altering a larger system. The physical work sits alongside the hydraulic requirement.

A sewage pipe exposed in an excavation, and a full-port non-return valve installed on it before the chamber is built
  • Buried services, chamber and pipe depths, ground conditions
  • Proximity to foundations, vehicle loading, confined-space risk
  • Chamber condition and future inspection and maintenance access

Building Regulations. Approved Document H recognises that sewers can surcharge in heavy rainfall, and identifies anti-flooding valves or pumped drainage for low-lying properties and basements with sanitary appliances.

Maintenance. A non-return valve is not fit-and-forget. It must stay accessible to inspect, clean, operate and replace. A shallow chamber is a very different job from one several metres down.

The location needs to work hydraulically, physically and for the person who will maintain it.

Different properties

Backflow protection for homes, flats & commercial.

A new inspection chamber with a full-port non-return valve set into the paving outside a house

01

Homes

A simple arrangement with a clearly vulnerable pipe can be straightforward. Basement drainage, several runs or past alterations may need investigation first.

Backflow protection for a lower-ground flat on shared drainage

02

Flats & shared drainage

Several properties may share drainage. Protecting a lower-ground flat must consider incoming surcharge and what happens to wastewater from elsewhere when a valve closes.

Flood on a larger commercial drainage network

03

Commercial

Larger networks, deeper drainage, specialist discharges and vehicle-loaded chambers. The same principles apply, with more detailed investigation and engineering input.

Ownership

Who is responsible for the drainage?

Diagram of a drain run from a property to the road: the private drain is the property owner's responsibility, the lateral or shared drain and the public sewer are the sewerage undertaker's

Drainage serving only one property within its boundary may be the owner’s responsibility, while shared and public sewers may be the sewerage undertaker’s. Establish this before altering shared or public drainage. Leasehold, managed and commercial properties may have separate responsibilities too. See Thames Water guidance on pipe responsibility.

Gallery

Backflow protection in practice.

Installations vary with the drainage, access and part of the network protected.

Need help with backflow protection?

If you know which valve is required, or have a drainage design or survey, contact us and we can supply and install. If the drainage or protection location is not yet established, investigation and design may be needed first, through FPS Environmental Ltd, the separate consultancy company in the FPS Group; once the requirement is set, we handle the product and installation.

Prefer to talk?

0115 987 0358

Monday to Friday, 9am to 5pm. For a made-to-measure barrier, use the quotation form on our FPS Barrier, Nautilus, door, driveway or garage barrier pages. It takes the measurements and photographs we need.

Send us a message

We normally reply within one working day.

We use these details to reply to your enquiry. See our Privacy Policy (opens in a new tab).

Please note: flood risk assessments, drainage design and consultancy are handled separately by FPS Environmental Ltd.