UK flood barrier supplier since 2012 Sole UK distributor of Water-Gate

Flood barriers · Guide

How to measure and install a flood barrier.

For most openings, measuring for a flood barrier is straightforward. We mainly need to understand the opening, its dimensions, the surrounding wall and the surface onto which the barrier will seal.

This guide shows what to measure and what we need, and the key principles for installing a demountable barrier.

Measuring the height of a doorstep above the surrounding ground with a tape measure
Specialist flood protection since 2012
  • Engineer-led advice
  • Made-to-measure systems
  • Quotes from your photos and measurements
  • Professional installation in selected areas

Measuring

How to measure for a flood barrier.

Measuring for a flood barrier is normally straightforward. For most openings, all you need is a tape measure, a phone or camera and, if available, a spirit level. A spirit level can help establish whether the surface beneath the barrier is flat and level. If you do not have one, do not worry. Clear photographs will still help us assess the opening. Our short film shows how to measure a typical doorway and some of the features to look out for.

  • 1
    What type of opening it is

    For example a door, French doors, garage or gateway.

  • 2
    Whether the door opens inwards or outwards

    It affects where the rails can sit and how the barrier clears the door.

  • 3
    Your desired barrier height, if known

    If you are not sure, say so and we will advise.

  • 4
    The aperture width

    Normally measured solid wall to solid wall.

  • 5
    A clear photograph of the opening

    Showing the whole opening, the walls on either side and the ground.

  • 6
    The reveal depth

    Where the opening is set back within a reveal.

  • 7
    The projection of the doorstep or threshold

    Where it projects beyond the wall.

  • 8
    The height difference between external ground and the threshold

    Measured from the external ground to the doorstep, threshold or internal floor level.

  • 9
    Details of any nearby obstructions

    Such as window ledges, pipework, cables, meter boxes or projecting brickwork.

Prefer to work from paper? Download the printable measuring guide.

Loading the video

The dimensions

Why we ask for each dimension.

Diagram from the FPS measuring guide showing the aperture width, barrier height, reveal depth and threshold projection

Barrier height should ultimately reflect the flood risk and the property or opening being protected, along with the structural suitability.

From the photographs we can normally establish whether a face-fixed or reveal-fixed arrangement is likely to be required. The additional dimensions help us make sure there is adequate space for the rails and identify anything that may affect the installation.

Face fix or reveal fix

Two ways a barrier fixes to the opening.

Which one suits your doorway decides what you measure: the clear opening for a reveal fix, or the opening plus a margin onto the wall each side for a face fix. If you would like to understand the difference first, read face fix compared with reveal fix.

Face fix drawing: the channels sit on the face of the wall either side, so the barrier is wider than the opening

Face fix

The barrier and its channels mount on the flat face of the wall, in front of the opening, overlapping onto the wall each side. The more forgiving option where the reveals are not square, sound or deep enough to fix into. Measure the opening plus the margin onto the wall each side.

Reveal fix drawing: the channels sit inside the opening, so the barrier is the width of the opening

Reveal fix

The barrier seats within the opening and fixes to the sides, the reveals, sitting neatly inside it. Suits sound, square reveals of enough depth, common on newer, regular doorways. Measure the clear opening at its narrowest point, brick to brick.

Not sure which you need? Face fix or reveal fix? Which fixing you need explains both, or send a photograph of each side of the opening and we will tell you.

The sealing base

Check the ground too.

A ground strip fixed and sealed to the surface beneath a flood barrier

FPS and Nautilus barriers compress down onto the surface beneath them, so they require a suitable, stable sealing base.

Sometimes the existing surface is already suitable. For example, a sound, flat and level concrete step may mean installation is very straightforward, potentially requiring little more than correctly fixing and sealing the wall rails.

In many installations some ground preparation is required, which is entirely normal. Surfaces such as block paving do not provide a suitable direct sealing base because the individual blocks and joints do not form the continuous, stable surface the barrier requires.

Read more about flood barriers on block paving, masonry preparation and installing ground inserts.

Printable guide

Download our measuring guide.

Want to take the measurements before completing the quote form? Our printable guide shows what to measure, where to measure it and why we ask for each dimension, with space to record your measurements as you go.

Measurements ready? Send them with your photographs and get a quote.

Installation

Already have a barrier, or planning your installation?

A face-fixed flood barrier installed to a front door with 50mm rail packing and black rails

The second half of this guide covers what matters when a demountable flood barrier is installed, whether we install it or you do.

Supply and installation

How to install a flood barrier.

Flood Protection Solutions installs flood barriers on suitable projects, but many of our systems are also supplied for customers, builders, facilities teams and other competent contractors to install.

We supply flood barriers throughout the UK and ship internationally on a supply-only basis.

The exact installation method depends on the barrier system and the site, so the product-specific instructions supplied with the barrier should always be followed. However, there are several important principles which apply to most demountable flood barrier installations.

Before Install

Key installation considerations.

What to think about before and during the installation of a demountable flood barrier.

Suitable walls and foundations

Suitable walls and foundations

A flood barrier transfers water pressure into the structure to which it is fixed. The wall, post, floor or foundation therefore needs to provide a suitable substrate for the required fixings and anticipated loads. The condition and construction of brickwork, masonry, concrete and other substrates should be considered before installation. Where structural adequacy is uncertain, further assessment may be required.

A suitable sealing surface

A suitable sealing surface

A flood barrier relies on its seals as well as the barrier boards themselves. The side and bottom seals need suitable surfaces against which to compress. Damaged masonry, irregular stonework, gaps or other defects may therefore require preparation as part of the installation.

Flat and level ground

Flat and level ground

The bottom of the barrier needs a suitable surface against which to seal. Where paving or the threshold is uneven or not sufficiently level, a ground strip may be required to create a consistent sealing surface. Any ground strip must itself be correctly fixed and sealed to the underlying surface.

Correct rail positioning

Correct rail positioning

The side rails need to be positioned so that the barrier can be installed correctly while clearing doorsteps, sills, handles, windows and other nearby features.

Fixings and sealing

Fixings and sealing

The appropriate fixings will depend on the barrier system and the material into which it is being installed. Rails, posts, ground strips and other permanent components also need to be appropriately sealed so that water cannot simply pass around or beneath the installation.

Always follow the installation instructions supplied for the particular barrier system.

After installation

Check the barrier after installation.

A doorway flood barrier being test fitted after installation

Once installed, assemble the complete barrier and check that:

  • barrier boards fit correctly;
  • seals compress as intended;
  • locking or compression mechanisms operate correctly;
  • the barrier can be installed and removed without obstruction; and
  • all removable components can be safely stored when not required.

Flood protection equipment should also be periodically inspected and maintained so that it remains ready for use.

Gallery

See how our flood barriers are installed.

Every property and opening is slightly different. These photographs show barriers being installed in real situations, including face-fixed and reveal-fixed installations, ground strips, wider openings and other site-specific details.

Installation guidance

Product-specific installation guidance.

Installation varies between barrier systems. Always work to the guidance supplied with the barrier you have.

Two ways to buy

Supply only, or installation by us.

Request a flood barrier quote.

Send us the opening dimensions and photographs and we can consider the barrier configuration required for quotation. For most openings we can advise on face fix or reveal fix, and provide a price, without a site visit.

Orders, deliveries and existing quotations

0115 987 0358

For new made-to-measure enquiries, please use the quotation form so we receive the dimensions, photographs and project information required.

Three short steps · about two minutes

Request a quotation

Photographs help us give a more accurate recommendation. Include the full opening, the threshold and the surrounding walls where you can.

We use these details to reply to your enquiry. See our Privacy Policy (opens in a new tab).

Please note: flood risk assessments, drainage design and consultancy are handled separately by FPS Environmental Ltd

Get a quote Get a quote